Computer-guided flapless placement and immediate loading of four conical screw-type implants in the edentulous mandible.
dc.contributor.author | Wittwer, G. | |
dc.contributor.author | Adeyemo, W.L. | |
dc.contributor.author | Wagner, A. | |
dc.contributor.author | Enislidis, G. | |
dc.date.accessioned | 2019-10-24T14:28:37Z | |
dc.date.available | 2019-10-24T14:28:37Z | |
dc.date.issued | 2007-08-01 | |
dc.description | Staff publications | en_US |
dc.description.abstract | AIM: The aim of this prospective study was to evaluate the outcome of computer-guided flapless placement and immediate loading of four conical screw-type implants in the interforaminal region. PATIENTS AND METHODS: From May to August 2003, 25 consecutive patients (m : f=16 : 9) with edentulous mandibles were included in the study. After transmucosal drilling with computer-assisted navigation, four implants were placed in the interforaminal region. The lower dentures were converted and implants immediately loaded. RESULTS: One-hundred implants were successfully placed. In two patients, all implants had to be submerged because of insufficient primary stability of one of the implants; another patient declined to receive immediate loading of implants after surgery and was lost to follow-up. During follow-up of the remaining 22 patients with 88 immediately loaded implants, loosening of four implants (4.5%) was seen in three patients. In these cases, immediate loading was terminated and all implants submerged; subsequently, two implants were lost in one patient, while the other two implants re-osseointegrated. The cumulative survival and success rates of immediately loaded implants were 97.7% after 2 years. Prosthetic success was 100%. CONCLUSION: Transmucosal computer-assisted placement and immediate loading of mandibular implants is a high-end approach to edentulism that provides excellent results while being minimally invasive. | en_US |
dc.identifier.citation | Wittwer G, Adeyemo WL, Wagner A, Enislidis G. Computer-guided flapless placement and immediate loading of four conical screw-type implants in the edentulous mandible. Clin Oral Implants Res. 2007 Aug;18(4):534-9. | en_US |
dc.identifier.uri | https://ir.unilag.edu.ng/handle/123456789/6503 | |
dc.language.iso | en | en_US |
dc.publisher | Wiley | en_US |
dc.relation.ispartofseries | Clin Oral Implants Res.;Vol.18(4) | |
dc.subject | computer-assisted surgery | en_US |
dc.subject | Flapless | en_US |
dc.subject | Implant placement | en_US |
dc.subject | Immediate loading | en_US |
dc.subject | Research Subject Categories::ODONTOLOGY | en_US |
dc.title | Computer-guided flapless placement and immediate loading of four conical screw-type implants in the edentulous mandible. | en_US |
dc.type | Article | en_US |