dc.description.abstractThe prevalent of failure of small structures (bungalow) in Iwaya area, Lagos, southwestern, Nigeria was investigated with a view to evaluating factor(s) responsible for many defective buildings in the area. Ten Vertical Electrical Soundings(VES) and five Cone Penetrometer Tests(CPT) were carried out on five traverses. One borehole was drilled close to a distress structure. Disturbed and undisturbed samples recovered from the borehole were used for grain size analysis, oedometer test and quick undrained triaxial test at depths(m) of 12.75,16.50 and 33.75m. Standard Penetration Tests (SPT) were carried out in cohesionless soil at depth of 34.00, 36.00 and 39.00 m. The VES revealed three to four Geoelectric layers composed essentially of topsoil (17.8-37.3 ohmmeter) made up of fill materials, relatively thick soft clay/ peat(2-12ohm meter) of 13.8-25.3m thickness, overlying clay/sandy clay layer (28-115 ohmmeter). The CPTs showed an area with markedly varying bearing capacities at depth of 0-15.25m. Cone resistance varies from 8-128kg/cm2, having very low cone resistance (2-5.4kg/cm2)up to depth of 13m in some areas. Computed allowed bearing capacity (qa) varies from 5.4-394.2KN/m2 while in areas with distressed small structures, the qa is mostly 5.4KN/m2 up to a depth of 10-12m confirming presence of soil too weak to support small loads. The SPT revealed the occurrence of medium dense sandy unit having N-value of 12-28, at depth of 34.0-40.0m. The values of cohesion at 65.5, 12.75 and 33.75m are 65KN/m2,50KN/m2 and 72KN/m2,with corresponding angles of internal friction of 10°, 7° and 12° respectively Computed settlement of compressible clay layer gave 212mm for a load of 15KN/m2 imposed on the peaty/soft clay. Preponderance of distressed small structures was caused by shallow foundation soil of very low strength, underlain by highly compressible clay in the area characterized by widely varying lithological facie.en_US
dc.identifier.citationOloruntola, M.O. [Et...al] (2018). Investigation of causes of structural distress in Iwaya area, Lagos, southwestern Nigeria.en_US
dc.identifier.issn2143-3275
dc.identifier.urihttps://ir.unilag.edu.ng/handle/123456789/5813
dc.language.isoenen_US
dc.publisherCenter for Applied Science and Technology Research/Faculty of Apllied Science and Technology, IBB University , Lapai, Niger stateen_US
dc.subjectBearing capacityen_US
dc.subjectDistressen_US
dc.subjectGeotechnical investigationen_US
dc.subjectDifferential settlementen_US
dc.subjectResearch Subject Categories::TECHNOLOGYen_US
dc.titleInvestigation of causes of structural distress in Iwaya area, Lagos, southwestern Nigeriaen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-DJOSTER 2018-investigation of causes of structural distress in Iwaya area.pdf
Size:
32.27 MB
Format:
Adobe Portable Document Format
Description:
Main Article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: