Distribution of Polychlorinated biphenyls in Environmental samples from an electrical power station in Lagos, Nigeria

dc.contributor.authorFolarin, B. T.
dc.contributor.authorOluseyi, T. O.
dc.contributor.authorOyeyiola, A. O.
dc.contributor.authorOlayinka, K. O.
dc.contributor.authorAlo, B. I.
dc.date.accessioned2019-08-29T12:49:25Z
dc.date.available2019-08-29T12:49:25Z
dc.date.issued2018-10-28
dc.descriptionStaff Publicationsen_US
dc.description.abstractConcentration levels of 12 PCB congeners (PCB-18, 28, 31, 44, 52, 101, 153, 118, 138, 149, 180 and 194) were determined in soil, dust, sediment and water samples collected at Ijora Olopa Power Station, Lagos, Nigeria. The calibration factors of target PCBs were estimated to test the linearity of the GC-ECD within a concentration of 0.025 ng/µL to 0.400 ng/µL. RSD of the calibration factors ranged from 4.6% to 12.3%, indicating a good response. Mean total PCBs in samples increased in the order water < soil < dust < sediment, with average values of 23.0 ng/mL, 27.3 ng/g, 272.6 ng/g, and 510.6 ng/g respectively. One way ANOVA revealed the mean concentrations of PCBs in the four sample types to be statistically different. The study provides a baseline report on the presence of PCBs in environmental samples from an electrical power facility in Lagos, Nigeria.en_US
dc.identifier.citationFolarin, B. T., [Et...al] (2018). Distribution of Polychlorinated biphenyls in Environmental samples from an electrical power station in Lagos, Nigeria. Journal of Taibah University for Science, Vol.12(6), 852-857.en_US
dc.identifier.urihttps://ir.unilag.edu.ng/handle/123456789/4873
dc.language.isoenen_US
dc.publisherTaylor and Francis Groupen_US
dc.relation.ispartofseriesJournal of Taibah University for Science;Vol.12(6)
dc.subjectpolychlorinated biphenyls (PCBs)en_US
dc.subjectDusten_US
dc.subjectpower stationen_US
dc.subjectsoilen_US
dc.subjectwateren_US
dc.subjectResearch Subject Categories::NATURAL SCIENCES::Chemistry::Analytical chemistry::Separation methodsen_US
dc.titleDistribution of Polychlorinated biphenyls in Environmental samples from an electrical power station in Lagos, Nigeriaen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
folarin2018.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
Description:
main article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: